Become a wholesaler Purchase Orders Info Contact Us
 
Vista-20ps Symphony CompatibleCode: Vista-20ps
Alarm Systems  >>  Ademco Vista Control


Send To Friend|Add to Wishlist|Write a Review
Vista-20ps Symphony CompatibleCode: Vista-20ps

Features:

Features Eight on-board hardwire zones standard (15 when Zone Doubling feature is used) Expandable to 48 total zones when used with hardwired and/or wireless expansion modules Wireless keys can be programmed without using zones 16 output devices Relays (Model 4204 Relay Modules, or 4229 Expansion Module), and/or X-10 devices (when used with a 4300 Transformer) Two low current on-board trigger outputs 100 Event Log viewable at system keypads with time/date stamp 48 system user codes assignable to either partition Two independent partitions plus a common partition Global Arming from any system keypad Goto function to view or operate one partition from the other Separate partition account numbers Four installer configurable zone types allows the installer to create custom zone types by assigning all zone attributes Multiple actions on output devices depending on system "state" Turns lights off when system arms Turns the same light on when system disarms Flashes same lights when system is in alarm Built-in phone line cut monitor with programmable delay and annunciation options Display on system keypads Trigger local sounders Trigger system bell Supports four-wire, and up to 16 two-wire smokes Works with Sentrol CleanMe maintenance signal Valuable End User

Features Compatible with ADEMCOs Graphic User Interfaces Now viewable on system keypads: Exit countdown Time and date display* Event log* Auto keypad backlighting on entry Keyswitch arming Programmable macro buttons and single-button arming A variety of wireless remote controls for single-button operation User Scheduling Automatically activates X-10 and relays at programmed times Latchkey reports to pagers Auto arm/disarm "User access" time windows Supports up to four end user numeric pagers VIP Module allows system control from any touchtone phone Chime by zone Security Dealer Features False alarm prevention features to help reduce false alarms Automatic System Load Shed During extended AC power fail, the system battery will be disconnected to prevent irreversible battery failure. Reduces service calls to replace batteries Dynamic Signaling Reduces redundant reporting to the central station when multiple reporting methods are used; i.e. digital dialer and AlarmNet radio *Requires custom alpha keypad Specifications (Return to top) Electrical Aux. power 12VDC, 600mA maximum Seven hour standby at 400mA aux. load with four amp hour battery 16.5VAC/25VA transformer Alarm output 12VDC, 2.0 amps maximum For UL installations, combined aux. and alarm output cannot exceed 700mA Output Control Supports up to four relay boards (up to 16 relays) Optional X-10 transformer/interface (part no. 4300) may be used to control up to 16 X-10 receiving devices Zones Eight hardwired zones (15 with zone doubling) Selectable response 10msec, 350msec, 750msec Assignable to any partition 20 selectable zone types plus four configurable zone types Programmable swinger suppression Expansion Devices 4219 Eight hardwired zones 16mA 4204 Up to four relays 15mA standby (each active relay draws an additional 40mA) 4229 Eight hardwired zones and two relays 36mA (each active relay draws an additional 40mA) Accessories 4286 VIP Voice Module 220mA 5881ENL RF Receiver supports up to eight zones 60mA, 5881ENM supports up to 16 zones 50mA, 5881ENH up to 40 zones 50mA 5883 Transceiver supports up to 40 zones 80mA Supports Eagle 1225 and 1221 boards Keypads 6160 Custom English (required for programming) 150mA/40mA (6160) 130mA/40mA (6139) 6160V.

Custom English with voice 150mA/40mA 6148 Fixed English LCD 70mA/30mA 6150 Fixed English LCD 70mA/40mA (6150), 40mA/20mA (6128) 6150RF Fixed English LCD with built-in receiver 105mA/80mA 6150V Fixed English LCD with voice 70mA/40mA 8132 Graphic touch-screen display Agency Listings UL Residential Fire, Burglary and CSFM UL approved for ANSI/SIA CP-01-2000 Smoke Detectors Supports up to 16 two-wire smoke detectors Supports four-wire smoke detectors Communications Touchtone or pulse Formats supported ADEMCO Contact ID ADEMCO 4 + 2 Express ADEMCO low speed Sescoa/Radionics 3 + 1, 4 + 1 and 4 + 2 reporting Reporting capabilities Split Dual Split/Dual True dial tone detection Low battery reports 11.2 11.6VDC AC loss and restoral reporting supported Ordering Information (Return to top) Part No. VISTA-20PS Description Control panel.


Customers who purchased this product were also interested in the following.
Outdoor Motion Detectors Photelectric Beam SERIES
Dual Photoelectric Beam Motion Detectors
 
Overhead Door Contacts-958
Adjustable magnet with L bracket for fast installation 24" armored cable is standard Standard gap -- 2-3/8" (60mm)
 
Pro55 Recessed Plunger contact
Recessed Plunger Contact 18" long wire leads Adhesive pads are pre-applied for fast easy installation. They need not be
 
 
Fluent Ecommerce Preferred Store ©2005, canalalarm.com. All rights reserved. email: webmaster@canalalarm.com